Choosing acoustic panels for offices requires more than comparing materials by appearance or thickness. In an open plan workplace, product selection needs to reflect how the space is used and how the acoustic system will be integrated into the overall office design.
This guide outlines the key factors to consider when selecting acoustic panels for open plan offices, from acoustic performance and panel types to installation, compliance, and project requirements.

The first step is to define what the office needs to improve. Open plan workplaces may have excessive reverberation, speech distraction, sound reflection, or unwanted sound transmission between areas.
These problems require different approaches. Acoustic panels mainly absorb reflected sound inside a room, while sound insulation measures are intended to reduce transmission between spaces.
A clear acoustic requirement gives the procurement team a better basis for comparing products than appearance or material type alone.
The position of workstations, meeting areas, circulation paths, reception zones, and shared spaces affects where acoustic treatment should be installed.
Large open areas with extensive hard surfaces can have more reflected sound than spaces with carpets, upholstered furniture, and existing ceiling treatment. Offices with exposed ceilings may also require a different approach from rooms with conventional suspended ceilings.
Reviewing the layout first helps determine whether wall panels, ceiling treatments, suspended elements, or a combination should be considered.
Acoustic performance is only one part of an office specification. The selected system may also need to meet requirements for fire performance, material composition, dimensions, appearance, installation, maintenance, and project quantity.
Recording these requirements before comparing suppliers makes the selection process more consistent and reduces unnecessary product comparisons.
NRC is commonly used to describe the sound absorption performance of an acoustic material. A higher NRC generally indicates greater sound absorption under the relevant test conditions.
RT60 measures how long sound takes to decay in a room after the sound source stops. Unlike a product rating, RT60 is affected by room volume, furniture, surface finishes, and installed acoustic treatment.
NRC can therefore help compare products, while RT60 can help evaluate the acoustic condition of the finished room.
Panel thickness alone does not determine the final acoustic result. Air gaps, backing materials, mounting systems, and surrounding construction can all affect performance.
This is especially important for wall mounted panels. A panel installed directly against a hard wall can perform differently from the same panel installed with an air cavity and additional insulation.
For example, OLI states that its slat wood panels can achieve up to 0.85 NRC depending on the air gap and insulation layer, while the actual acoustic performance varies with installation conditions.
Sound absorption and sound insulation address different problems.
Absorptive panels reduce reflected sound within a room. Sound insulation is intended to limit sound transmission between spaces. A product selected for reverberation control should therefore not automatically be treated as a solution for speech privacy.
Where privacy is important, walls, doors, glazing, partitions, ceiling construction, and other building elements may also need to be considered.
Wood slat acoustic panels can be considered when wall treatment needs to support both acoustic control and interior design. They are particularly relevant to offices where a structured wood finish forms part of the architectural concept.
OLI’s slat wood panel range uses MDF slats with real wood veneer or technical foil and a polyester felt backing. The current category also includes products specifically listed for offices and conference rooms.
For projects considering decorative acoustic wall systems, acoustic slat wood panels can be evaluated according to dimensions, finish, installation method, and acoustic data.

Polyester fiber panels provide another option for wall treatment when the project requires lightweight acoustic elements, visual customization, or flexible layouts.
The acoustic performance should be checked against the specific product specification. Thickness, construction, installation position, and surface configuration can influence the final result.
OLI’s polyester fiber acoustic panel category includes an office specific product as well as panels for other commercial applications. The polyester fiber acoustic panels range can therefore be reviewed according to the requirements of each office area.
Suspended acoustic elements can be considered when wall surfaces are limited or when the ceiling is an important part of the acoustic strategy.
They can add sound absorption without requiring every available wall to be covered. However, the suspension method, ceiling structure, panel dimensions, building services, and maintenance access should all be reviewed before specification.
OLI maintains a dedicated suspended acoustic baffles category. The current category includes a suspended ceiling product, while office specific application should be confirmed against the project requirements.
| Panel Type | Typical Office Application | Main Selection Factors | Key Consideration |
| Wood slat acoustic panels | Feature walls, work areas, meeting spaces | Finish, dimensions, backing, installation | Combines acoustic treatment with architectural appearance |
| Polyester fiber panels | Wall treatment, collaborative areas, flexible layouts | Thickness, shape, finish, acoustic data | Product specific performance should be verified |
| Suspended acoustic elements | Open ceilings, large open areas | Suspension system, ceiling structure, coordination | Useful when available wall surfaces are limited |
The table provides a starting point, but the final selection should be based on the actual room condition and product documentation.
Open workstation areas contain multiple sound sources across a large floor area. Treating only one wall may leave other reflective surfaces untreated.
Panels can be distributed across suitable walls or other available surfaces to support the overall acoustic strategy. Placement should consider desk orientation, circulation routes, glazing, exposed walls, and existing ceiling treatment.
The objective is to create a balanced treatment plan rather than simply covering the largest available surface.
Meeting rooms require a different approach because reducing internal reverberation does not necessarily prevent conversations from being heard outside the room.
Where speech privacy is important, the specification should consider the room enclosure as well as internal sound absorption. Walls, doors, glazing, ceilings, and adjacent spaces can all influence sound transmission.
Acoustic panels can improve the internal acoustic environment, but they should not replace appropriate sound insulation construction.
Open ceiling offices may contain exposed structural elements, lighting systems, mechanical equipment, and other building services. These conditions affect both acoustic treatment and installation.
Suspended elements can provide additional absorption without covering every wall. Their location should be coordinated with lighting, sprinklers, ventilation, cable trays, and maintenance access.
This makes ceiling coordination an important part of acoustic panel planning.
Before ordering panels, confirm whether the project requires direct fixing, adhesive installation, mechanical fixing, timber battens, suspended mounting, or another system.
The mounting method can affect both appearance and acoustic performance. OLI’s slat wood panel information lists glue, wood frame, gun nail, and screw installation options.
The selected method should be evaluated together with the substrate, panel construction, access requirements, and project drawings.
Commercial office projects may require documented fire performance and material information before products can be approved.
OLI’s slat wood panel category currently lists certified Class A ASTM E84 and Class B1 EN 13501-1 options, with the exact construction depending on the specified product.
Procurement teams should request documentation for the actual product and construction rather than applying a general rating to an entire category.
Maintenance requirements should be considered before final approval. Check whether individual panels can be removed, replaced, cleaned, or repaired without affecting adjacent finishes.
For larger projects, also confirm panel dimensions, finishes, replacement options, packaging, and installation requirements. These factors can affect long term maintenance after installation.
Record the main acoustic problem, room function, office layout, ceiling condition, and available surfaces.
This information provides a practical basis for discussions with an acoustic consultant or supplier.
Request the information needed to compare products consistently, including:
The information should relate to the actual product and installation configuration.
A product price alone does not represent the complete project cost. Compare the panels together with backing materials, mounting systems, supporting structures, installation requirements, transportation, and potential replacement needs.
For larger commercial projects, it is also useful to confirm whether the supplier can review drawings and provide relevant technical documentation before production.
Compare acoustic performance, panel construction, thickness, installation method, fire documentation, dimensions, finish, maintenance requirements, and project quantity. The comparison should reflect the intended installation rather than the material name alone.
They can be suitable when the project requires wall based acoustic treatment together with a wood architectural finish. The final selection should consider panel construction, installation method, acoustic data, fire requirements, and office design.
They can be considered when ceiling treatment is appropriate for the space. The suspension system, ceiling structure, building services, maintenance access, and product specific acoustic data should be reviewed before specification.
Choosing acoustic panels for an open plan office starts with the acoustic requirement and layout, followed by product performance, installation, and compliance.
For project specific panel options, finishes, dimensions, and technical documentation, contact OLI Acoustics with your office requirements for further discussion.
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. Show more
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.