The perforation pattern is a key factor in the acoustic behavior of a wooden panel. Changes in hole size, spacing, and distribution affect how sound interacts with the panel and the space behind it.
Understanding these relationships helps architects, acoustic consultants, contractors, and procurement teams evaluate perforated panels based on performance rather than appearance alone.
Hole diameter and perforation density affect how sound enters the cavity and how the panel absorbs sound. Different opening sizes and distributions create different acoustic responses, so the right configuration depends on the required performance and overall panel assembly.
For available pattern options, perforated acoustic panels can be reviewed alongside material and finish requirements.

The distance between adjacent holes determines how much of the panel surface remains open. At a similar hole diameter, changing the spacing changes the total open area and therefore the way sound reaches the material behind the panel.
Hole diameter and center spacing should therefore be considered together rather than evaluated independently. The final specification should also include panel thickness, backing, and cavity depth.
Panel thickness affects the physical structure through which sound enters the cavity, while cavity depth determines the space available behind the perforated face.
A panel with the same perforation pattern can therefore produce different results when its thickness, backing, or cavity changes.
Standard perforated patterns provide repeatable hole arrangements for projects where acoustic requirements and architectural appearance both need to be controlled.
The available configurations can vary in hole size, spacing, panel thickness, substrate, and finish. This gives designers flexibility to consider the perforation structure together with the visual requirements of the space.
Micro perforated panels use smaller and more closely arranged openings to create a denser perforated surface. This structure can provide a more visually continuous appearance while retaining the acoustic function of a perforated panel.
For example, the 4-2-0.5 micro perforated panel uses an E0 MDF core, white melamine finish, and a 600 × 600 × 15 mm format. The product page also identifies different material, finish, size, and customization options for this product range.

Custom perforation can be considered when a standard pattern does not match the project’s design or technical requirements. Hole arrangements, dimensions, finishes, and other specifications can be adapted for individual projects.
A custom pattern should not automatically be assumed to have the same acoustic performance as a tested standard configuration. When a project has a defined absorption target, the complete assembly should be reviewed before production.
The material behind the perforated face provides an important part of the absorption system by adding an absorptive layer inside the cavity.
Depending on the configuration, perforated wooden acoustic panels can use an acoustic felt or other backing material behind the perforated face. The backing should therefore be specified together with the panel rather than treated as a separate installation detail.
Air cavity depth changes the relationship between the perforated surface and the absorptive material behind it. The same perforation pattern can consequently perform differently when installed with different cavity dimensions.
A published laboratory test provides a useful example. The tested structure consists of a 16-16-6 perforated acoustic panel, 50 mm insulation foam, and a 100 mm cavity. The reported absorption coefficient reaches 0.78 at 160 Hz, 0.91 at 200 Hz, and 1.01 at 250 Hz, with an NRC of 0.74.
The 16-16-6 perforated acoustic panel is therefore a useful example of why acoustic test data needs to be considered together with the installation structure. The reported values describe the tested assembly rather than the panel alone.

Panel thickness, backing, cavity, fixing arrangement, and surface coverage should be considered together when defining the construction.
Standard panel thicknesses include 12, 15, and 18 mm, while panel sizes can be adapted for different wall and ceiling layouts. These specifications should be considered alongside the selected perforation pattern when preparing the project documentation.
A complete specification therefore provides more useful information than a pattern name alone.
Auditoriums and lecture halls require controlled reverberation and clear speech. Perforated wooden panels can combine sound absorption with a wood-based architectural finish, while the final performance depends on the selected pattern and installation assembly.
The perforated panel range is suitable for applications including auditoriums, lecture halls, conference rooms, multi-function halls, cinemas, offices, and other commercial or public spaces.
Office and meeting room applications often require control of reverberation and sound reflections while maintaining a suitable interior appearance.
A perforated wood surface can provide an architectural finish while the perforation structure and backing contribute to the acoustic treatment. Pattern selection should therefore consider both the room’s acoustic requirements and the desired visual effect.
Sports halls and multi-function spaces typically involve large wall or ceiling areas and demanding installation conditions.
Perforated acoustic panels can be specified with different substrates, finishes, thicknesses, and pattern configurations. For these projects, the perforation pattern should be considered together with the substrate, backing, installation structure, and required acoustic performance.
The specification should begin with the room’s acoustic objective rather than the appearance of a particular perforation pattern.
Determine the required reverberation control and the frequency range that requires greater absorption. The selected panel can then be evaluated against relevant acoustic test data.
A practical specification should cover the perforation pattern, panel thickness, core and backing materials, air cavity depth, dimensions, surface finish, and relevant acoustic test data. Considering these factors together helps ensure the specified panel matches the actual installation and expected acoustic performance.
Acoustic test results should always be reviewed together with the test construction.
For example, the published NRC of 0.74 for the 16-16-6 configuration is associated with a 50 mm insulation foam layer and a 100 mm cavity. The value should not automatically be applied when the actual project uses a different backing material, cavity depth, or mounting structure.
NRC values should therefore be compared only after the relevant test conditions have been reviewed.
Perforated wooden acoustic panels can be adapted through different substrates and surface finishes. Available options include MDF, HDF, MGO, and Black MDF, with finishes such as melamine, veneer, laminate, and paint.
Projects with unusual wall dimensions, ceiling layouts, or specific acoustic targets may also require customized panel dimensions or perforation configurations.
For projects requiring additional technical coordination, custom acoustic solutions can provide product recommendations, technical parameters, acoustic simulation, and installation guidance.
Perforation pattern selection should consider the complete acoustic assembly rather than the panel appearance alone. Hole configuration, panel thickness, backing, and cavity depth all contribute to the final acoustic response.
For projects with specific acoustic requirements, matching the perforation pattern with the tested assembly makes performance easier to evaluate and verify. To discuss project requirements or panel specifications, contact OLI for technical support.
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. Show more
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.