News

How to Reduce Noise in Restaurants with Acoustic Panels

A noisy dining room can make conversations difficult and reduce the comfort of customers and staff. Acoustic panels for restaurants can help control sound reflections and reverberation, creating a more comfortable acoustic environment without compromising the interior design.

The following sections explain the main causes of restaurant noise and the key considerations for reducing it with acoustic treatment.

Why Do Restaurants Become So Noisy?

Hard Surfaces Increase Sound Reflection

Restaurants contain many simultaneous sound sources. Customers talk across tables, tableware creates impact sounds, kitchen equipment produces mechanical noise, and background music adds another layer of sound.

Glass, tile, concrete, and other hard finishes can reflect much of this sound back into the room. As reflections build up, conversations become harder to follow and customers may naturally speak louder.

This type of acoustic challenge is also addressed in the restaurant acoustic solutions, which combine wooden sound absorbing wall panels, upholstered seating, and sound absorbing ceiling treatment. The stated target for this particular solution is a reverberation time below 0.8 seconds.

Sound Absorption and Soundproofing Solve Different Problems

Sound absorption controls reflected sound inside a room. Soundproofing deals with noise passing from one space to another.

For a dining room where conversations are difficult to hear, absorption is usually the more relevant approach. If restaurant noise is disturbing an adjacent room, the separating wall, floor, ceiling, or partition should also be assessed.

Understanding this difference helps restaurant owners avoid selecting a product based only on a general acoustic label when the actual problem requires a different type of treatment.

Reverberation Reduces Speech Clarity

Reverberation occurs when sound continues to reflect after the original sound. In a busy restaurant, these reflections can overlap with direct speech and reduce clarity.

Adding absorptive surfaces can help control this effect. The required amount depends on the room size, finishes, furniture, and occupancy, so treatment should be planned for the actual space rather than based on a fixed coverage percentage.

What Should You Consider When Choosing Acoustic Panels?

NRC Helps Compare Sound Absorption

NRC, or Noise Reduction Coefficient, is commonly used to compare sound absorption. When selecting panels for a restaurant, it is also important to understand how NRC differs from STC. The NRC rating guide explains this distinction, where NRC relates to sound absorption inside a room and STC relates to sound transmission between spaces.

NRC should not be viewed as the complete acoustic result. The amount of material, its location, and the installation structure also affect performance. A product with a higher laboratory rating does not automatically produce the same result in every restaurant.

STC Applies to Sound Transmission

STC is more relevant when noise passes through a wall, floor, ceiling, or partition. It is not a replacement for NRC when the main issue is reverberation inside the dining room.

The rating should therefore match the problem being addressed rather than simply being selected by numerical value. If both internal reverberation and noise transfer are concerns, the two requirements should be considered separately.

Fire and Moisture Requirements Affect Product Selection

Restaurant materials can be exposed to humidity, cleaning, food particles, and frequent contact. Fire performance must also meet the project requirements.

A 21 mm Walnut Acoustic Slat Panel offers Melamine, Veneer, and PVC finishes. Its product information also lists Class A and Class B fireproof grades according to requirements. The appropriate finish and classification should be confirmed for the installation area.

Which Acoustic Panels Are Suitable for Restaurants?

Wood Slat Panels Combine Acoustic and Decorative Functions

Wood slat panels can integrate acoustic treatment into the restaurant interior. A 21 mm Walnut Acoustic Slat Panel from OLI Acoustics uses MDF and polyester fiber, with a standard size of 2400 mm by 605 mm by 21 mm.

For projects considering a wood finish, the walnut acoustic slat panel is listed for restaurant applications and has a stated NRC range of 0.6 to 0.8. A laboratory NRC of 0.82 is reported for a specific structure using 50 mm insulation foam and a 100 mm cavity, so this result should not be applied to every installation.

Perforated Panels Provide a Structured Surface

Perforated panels use openings in the surface together with a backing structure for sound absorption. They can provide a more uniform architectural appearance while allowing different surface patterns and finishes.

Available options include MDF, HDF, MGO, and Black MDF, with standard thicknesses of 12 mm, 15 mm, and 18 mm. Different perforation patterns and finishes are available for projects with specific architectural requirements.

Polyester Fiber Panels Offer Design Flexibility

Polyester fiber panels can be considered when color, shape, and pattern are important to the interior design. Available options include 9 mm and 12 mm thicknesses and are described as sound absorbing and nonflammable.

They can add visual flexibility while providing acoustic treatment. The required acoustic performance and fire requirements should still be confirmed according to the project conditions.

Where Should Acoustic Panels Be Installed?

Ceiling Treatment Addresses Large Reflective Surfaces

The ceiling can be one of the largest reflective surfaces in a restaurant. A hard ceiling may continue returning sound to the dining area even after wall treatment is added.

When ceiling treatment is required, acoustic ceiling panels can be considered alongside wall treatment. The ceiling system should be coordinated with lighting, ventilation, sprinklers, electrical services, and maintenance access.

The appropriate ceiling solution depends on ceiling height, structure, room layout, and the amount of existing absorption.

Wall Treatment Should Follow the Room Layout

Wall panels do not need to cover every available surface. Priority should be given to areas that contribute significantly to reflection and affect the dining experience.

The main dining area may require more attention than service spaces. Private dining rooms and bar areas should be assessed separately according to their size, furniture, finishes, and typical occupancy.

Suspended Treatment Can Suit Large Open Spaces

Large dining rooms with high ceilings may benefit from acoustic elements installed at ceiling level. This adds treatment without using extensive wall space.

Suspended systems should be coordinated with the building structure and other ceiling services. Their quantity and position should be determined according to the room’s acoustic requirements rather than a fixed installation ratio.

How Should Restaurant Acoustic Projects Be Planned?

Room Information Should Be Prepared Before Ordering

Before requesting a quotation, restaurant owners should provide the room dimensions, ceiling height, wall and ceiling finishes, flooring, seating arrangement, existing soft furnishings, main noise sources, problem areas, and fire or finish requirements.

Photos, drawings, and acoustic measurements can also help suppliers understand the project more accurately. More complete information allows the acoustic solution to be matched more closely with the actual room conditions.

Limited Budgets Can Be Managed in Stages

A restaurant does not always need to treat every surface at once. A first stage can focus on the main dining area and the surfaces most responsible for reflections.

The result can then be reviewed before additional areas are treated. This approach allows the treatment plan to respond to the actual acoustic condition instead of assuming that every part of the restaurant requires the same level of treatment.

Installation Conditions Affect Acoustic Performance

The substrate should be stable, clean, dry, and suitable for the selected fixing method. For a 21 mm Walnut Acoustic Slat Panel, the installation guidance describes preparing the wall and leveling a wooden keel before installation. The listed methods include glue, wood frame, and gun nail.

Laboratory data should also be considered together with the tested installation structure. The reported NRC of 0.82 applies to a structure with 50 mm insulation foam and a 100 mm cavity. Different installation conditions may produce different results.

Conclusion

Reducing noise in a restaurant starts with understanding how sound moves through the space and where reflections are strongest. Acoustic panels can then be selected and positioned according to the room layout, acoustic requirements, interior finishes, and installation conditions.

For a project specific recommendation and quotation, contact OLI Acoustics with your room details, acoustic requirements, panel specifications, and order volume.

Related Products

We value your privacy

We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.

Get a Quote